Low Voltage Wiring Code in California | San Francisco, CA Guide

In San Francisco—or anywhere in California—ensuring that your low voltage wiring meets the correct code requirements is essential for safety, compliance, reliability, and passing inspections. “Low voltage” work may seem simpler than mains electrical, but it is still regulated under state safety orders, local amendments, and national standards. In this article, you’ll get a clear, up-to-date guide on the applicable codes for low voltage wiring in California (focusing on San Francisco), including definitions, mandatories, design restrictions, contractor licensing, permit requirements, and best practices.

Defining “Low Voltage” under California Code

To understand which code sections apply, you first need to know how “low voltage” is defined in California. Under the Low-Voltage Electrical Safety Orders (Group 1 of Title 8, Division 1, CCR), certain circuits are designated as Class 1, Class 2, or Class 3 remote control, signaling, or power-limited circuits. These circuits are subject to the rules established under those safety orders.

California also includes a section specifically titled “Low-Voltage Wiring” (8 CCR § 2773) that imposes isolation or grounding requirements when such wiring is part of a metal-enclosed bus run.

Thus, “low voltage wiring” in California refers to wiring for signaling, communication, control, or power-limited systems that fall under the safety orders rather than full power circuits.


Key Regulatory Frameworks & Authorities

Several overlapping regulatory authorities define the enforced standards:

  • California Code of Regulations (CCR), Title 8, Division 1 — Electrical Safety Orders: these include Group 1: Low-Voltage Electrical Safety Orders which cover wiring methods, definitions, uses, and operating rules.
  • National Electrical Code (NEC / NFPA 70) as adopted (with amendments) in California: the state, and local jurisdictions, adopt versions of the NEC and may impose modifications.
  • San Francisco Electrical Code (and amendments) — local jurisdiction may add or alter rules.
  • State licensing & oversight agencies, including contractor licensing bodies, inspectors, and building departments that enforce the code.

These layers interact: state safety orders provide baseline safety rules, NEC covers wiring methods and design, and local code may tighten or adjust requirements in San Francisco.


State Safety Orders: 8 CCR, Title 8, Low-Voltage Electrical Safety Orders

Scope & Structure

California’s Low-Voltage Electrical Safety Orders are organized under Title 8, Chapter 4, Subchapter 5, Group 1. They define rules for installations on systems of 600 volts or less, including low-voltage circuits.

Important articles include:

  • Definitions (8 CCR § 2300) — terms used across safety orders.
  • Work Procedures / Electrical Installations (Articles 3–4) — rules for general wiring, splices, conductor ratings.
  • Overcurrent Protection (Article 10), Grounding (Article 11) — even for low-voltage circuits, proper protection and grounding rules apply.
  • Wiring Methods, Components, Equipment (Article 12) — covers conduits, raceways, allowable cables.
  • Open Wiring (Article 16) — exposed wiring rules under controlled conditions. For example, open exposed wiring is disallowed in buildings except in restricted electrical-use spaces (8 CCR § 2420.3).
  • Low-Voltage Wiring (8 CCR § 2773) — when wiring is part of a metal-enclosed bus run, the low-voltage portion must be isolated by grounded metal or otherwise safely separated (i.e. control wires in bus duct must be isolated).

Also, rules regarding flexible cords and cables (8 CCR § 2584.5) stipulate that flexible cables must be continuous (no splices) between junctions, rated for usage (sunlight resistance outdoors, wet locations), and not laid on the ground unless listed for that use.

These safety orders set mandatory minimum safety requirements for low-voltage electrical systems in California, including those in San Francisco.


Wiring Methods & Restrictions under California Code

When implementing low-voltage wiring in California, the following wiring method rules and restrictions apply under the adopted safety orders and code:

Flexible Cords & Splices

Flexible cords and cables must be continuous (no mid-run splices) between boxes or fittings. They must be listed for the intended use (e.g. outdoor, wet location) if used outdoors or exposed to sun. (8 CCR § 2584.5)

Open Exposed Wiring

Open exposed wiring is largely prohibited in buildings, except in certain limited spaces (transformer vaults, substations, tunnels restricted to electrical access). (8 CCR § 2420.3)

Isolation in Bus Ducts

When low-voltage, signaling, or control circuits are run as part of a metal-enclosed bus run system, they must be isolated by grounded metal or equivalent separation. (8 CCR § 2773)

Outdoor Wiring & Conduits

Low-voltage wiring exposed outdoors must comply with the “Outdoor Wiring” articles under the safety orders, which cover conductor ratings, support, routing, and protection from environmental exposure.

Listed / Approved Equipment & Methods

All wiring methods, cables, connectors, and conduits must be listed and permitted by the safety orders or referenced standards. Use of non-listed or unapproved methods is not allowed.

Separation from Power Circuits

Even though low-voltage cabling carries minimal power, circuits must maintain separation from higher-voltage power conductors to prevent interference, induced voltages, or safety compromise, following NEC rules (as adopted) and safety orders.


San Francisco & Local Amendments to Electrical Code

In San Francisco, the city adopts its own version of the electrical code (often based on a recent electrical code edition) with local amendments. One relevant example:

  • The San Francisco Electrical Code includes “Low Voltage Lighting” provisions: for conductors concealed or extended through walls, floors, ceilings, or suspended ceiling, they must comply with wiring methods specified in Chapter 3 or wired per Class 2 (or similar) power source rules.
  • San Francisco’s code may forbid use of flexible cord-and-plug connections in some fixed or emergency wiring scenarios.

Thus, a low-voltage installation in San Francisco must satisfy both state safety orders and the local San Francisco amendments. It’s critical to reference the latest published San Francisco Electrical Code (and any local amendments) in design.


Licensing & Scope: Who Can Perform Low Voltage Work

California regulates which contractors may legally perform low-voltage wiring projects.

C-7 Low Voltage Systems Contractor

Contractors performing energy-limited, communication, signaling, security, audio/visual, low-voltage landscape lighting, and similar systems typically fall under the C-7 license category. These systems are usually limited to ≤ 91 volts or energy-limited circuits under pairing definitions set by licensing boards.

When a C-10 or Other License Is Required

If a job involves circuits or wiring beyond the low-voltage category—such as power circuits, high-voltage systems, or major electrical work—those portions must be handled by a contractor licensed under C-10 Electrical Contractor or another appropriate license.

Therefore, in San Francisco or elsewhere in California, the low-voltage portion should be executed by a properly licensed C-7 contractor, and more complex work by others as needed.


Permits, Inspections & Code Enforcement in San Francisco

Even though low-voltage work is “lower risk” than mains power, many installations do require permits, inspections, and compliance review in San Francisco.

Permit Requirements

Local jurisdiction (San Francisco Building Department or Electrical Division) may require that any significant low-voltage wiring project be permitted. Projects involving penetration of fire barriers, pathways through shared walls, fire-rated separation, or combining with other systems often trigger permitting.

Inspection & Code Compliance

Installed wiring must remain open until inspected and verified to comply with codes and safety orders. Concealing wiring prematurely is prohibited. Inspectors may verify wire types, junctions, terminations, pathway routing, grounding/isolation compliance, and labeling.

Enforcement & Local Authority

San Francisco’s code enforcement can require correction, removal, or rework of installations that violate code. In critical facilities or public works (e.g. Port of San Francisco), a permit is mandatory and work must be inspected under code.

Thus, always plan designs anticipating review and enforcement.


Best Practices & Common Pitfalls

To ensure compliance and performance, observe these best practices and watch for pitfalls:

  • Adhere strictly to safety orders and local code — don’t assume low voltage is exempt.
  • Use listed components and methods — only use cables, connectors, conduits rated for their application (e.g. damp locations, sunlight resistance).
  • Avoid splices in flexible cord runs — maintain continuity between junction boxes.
  • Maintain separation from power wiring — avoid parallel runs and keep proper spacing.
  • When integrating with metal bus systems, isolate low-voltage wiring as required.
  • Document installations — clearly label wiring, junctions, and paths so inspections are easier.
  • Consult latest local San Francisco code — local amendments may override or tighten rules.
  • Hire properly licensed contractors — ensure they are C-7 (or whatever license applies) and understand safety orders.
  • Don’t conceal wiring before inspection — keep wiring accessible until signed off.
  • Plan for future expansion — leave slack, spare conduits, and flexible “reserve” capacity.

Conclusion

Low voltage wiring in California, including San Francisco, is governed by a layered regulatory system: state safety orders, adopted electrical code (NEC with amendments), and local jurisdictional modifications. Even though such systems handle lower voltages, they are not exempt from rigorous safety, isolation, wiring method, and inspection rules. For any project in San Francisco, you must ensure your designs and installations comply with 8 CCR Title 8 Low-Voltage Safety Orders, meet San Francisco’s local electrical code amendments, and be performed by properly licensed contractors with inspections. Doing so ensures safety, avoids costly rework, and delivers reliable functionality.

FAQ